Hioki 7016 Signal Source Generator, 50mV to 250V AC/DC
Incorporates high-performance DMM functions into a handy signal generator
Convenient pulse source for calibrating flow meters
as well generation of constant current and constant voltage
Amazon.co.uk Price: £1,537.00 (as of 03/10/2019 09:13 PST- Details)
Usually, in 7-21 working days, customers can get the orders after issuing the order. However, we will do our best to dispatch it as soon as possible. If you are urgent, please make us informed it in time. & Signal source incorporates high-performance DMM functions into a handy signal generator to provide a convenient, multi-function calibrator at a low price. In addition to generating constant voltage and constant current, it generates pulse signals such as the voltage pulses used for calibrating flow meters and similar devices. Along with its many signal generator functions, the substantial stand-alone DMM measurement functions of model 7016 include AC and DC voltage and current, resistance, frequency and temperature, and continuity checking. Moreover, with the optional 3856 Communication Package, measured values can be sent to a PC, which can also control functions such as source voltage settings and measurement range selection. It gives you multiple functions, high precision and high performance at low cost in an instrument that is suitable for use in the laboratory as well as in the field. DC constant voltage generation: +/-1.5000V, Accuracy: +/-0.03 percent of setting +/-3 dgt., +/-15.000V, Accuracy: +/-0.03 percent of setting +/-3 dgt. DC constant current generation: +/-25.000mA, Accuracy: +/-0.03 percent of setting +/-5dgt. Pulse generation: 0.5 to 4800Hz, Accuracy: +/-0.005 percent of setting +/-0.01 Hz. Measurement functions: DC voltage, AC voltage, AC+DC voltage, DC current, AC current, AC+DC current, Resistance, Diode test, Continuity test, Temperature, Frequency, Duty ratio, Pulse width. Voltage measurement: DC voltage, AC voltage, AC+DC voltage, 1 ms peak-hold voltage: +/-51.000mV to +/-250.00V, 5 ranges, (Represented DC V accuracy: +/-0.03 percent rdg. +/-5 dgt). Current measurement: DC current, AC current, AC+DC current, 1 ms peak-hold current: +/-51.000mA to +/-510.00mA, 2 ranges, (Represented DC A accuracy: +/-0.03 percent rdg. +/-5 dgt).
Incorporates high-performance DMM functions into a handy signal generator
Convenient pulse source for calibrating flow meters
as well generation of constant current and constant voltage
Bipolar sink/source generation expands test utility
High resolution
Specification: Hioki 7016 Signal Source Generator, 50mV to 250V AC/DC
Brand |
---|
User Reviews
Be the first to review “Hioki 7016 Signal Source Generator, 50mV to 250V AC/DC”
You must be logged in to post a review.
There are no reviews yet.